a5:programmable-power-supply-control [2018/07/05 20:31] โ€“ [Use New Functions] aeketa5:programmable-power-supply-control [2020/12/25 02:13] (current) โ€“ external edit 127.0.0.1
Line 4: Line 4:
 The changes shown here require knowledge in the field of Arduino, Marlin firmware and electrical engineering and can overwhelm normal users. Also, I would like to point out possible dangers that exist in certain interventions. All adjustments have been checked for function.  The changes shown here require knowledge in the field of Arduino, Marlin firmware and electrical engineering and can overwhelm normal users. Also, I would like to point out possible dangers that exist in certain interventions. All adjustments have been checked for function. 
  
-**Difficulty: Professional** (No more warnings. Professionals know when to unplug the mains)+**Difficulty: __Professional or Electrician__** (No more warnings. Professionals know when to unplug the mains)
  
 **What is this about?** \\  **What is this about?** \\ 
Line 63: Line 63:
 ==== Customize the Marlin firmware ==== ==== Customize the Marlin firmware ====
  
-In the Arduino IDE open the **A5 Custom Community Firmware** (see article here in WIKI).\\+In the Arduino IDE open the **A5 Custom Community Firmware** (see [[a5:firmware|article here]] in WIKI).\\
 __ __
 The following adjustments are made in the "**Configuration.h**" file:__ The following adjustments are made in the "**Configuration.h**" file:__
Line 145: Line 145:
  
 I had developed a complex special housing for the momentary switch and the solid state relay, in which the circuit should find its place. This would look like this: I had developed a complex special housing for the momentary switch and the solid state relay, in which the circuit should find its place. This would look like this:
 +
 {{:a5:aetek:ssr_pow_01.jpg}} {{:a5:aetek:ssr_pow_01.jpg}}
 +
 Electrically everything worked wonderfully. Unfortunately I noticed a problem after assembling the A5. The measurement of the available space above the momentary switch upper edge was wrong. The Y-gantry does not have enough room to move because the housing of the momentary switch was too high.\\ Electrically everything worked wonderfully. Unfortunately I noticed a problem after assembling the A5. The measurement of the available space above the momentary switch upper edge was wrong. The Y-gantry does not have enough room to move because the housing of the momentary switch was too high.\\
 \\ \\
Line 181: Line 183:
 AETEK Firmware:\\ AETEK Firmware:\\
 {{:a5:aetek:20180702-03_aetek_jgaurora_a5_custom_lcd_firmware_v3.02.zip}} \\  {{:a5:aetek:20180702-03_aetek_jgaurora_a5_custom_lcd_firmware_v3.02.zip}} \\ 
-\\+{{:a5:aetek:20180714-02_aetek_jgaurora_a5_custom_lcd_firmware_v3.02.zip}} Fix Filament Out Detection\\
  
 After the successful update of the MKS display firmware it should now look like this:\\ After the successful update of the MKS display firmware it should now look like this:\\
Line 218: Line 220:
 === Operation via software (GCODES) === === Operation via software (GCODES) ===
  
-GCODES can be sent directly to the A5 via USB, e.g. Pronterface. \\+GCODES can be sent directly to the A5 via USB, e.g. [[:pronterface|Pronterface]]. \\
 There is also the option to send stored GCODES from a storage device, such as USB stick or SD card. \\ There is also the option to send stored GCODES from a storage device, such as USB stick or SD card. \\
 Which GCODES are of interest for this project?\\ Which GCODES are of interest for this project?\\
Line 240: Line 242:
 //M109 R45// \\ //M109 R45// \\
 \\ \\
 +\\
 +__**Application proposals**__\\
 +Every modern slicer program, such as Simplyfy 3D, Cura, Slic3R, etc., has the ability to define a START and END GCODE block. Among other options you can also enter commands for the control of the power supply. \\
  
-More content is coming soon...\\ 
  
 +\\
 +Example: Simplyfy 3D\\
 +<code>
 +;STARTING GCODE START --- Simplyfy 3D ----------------------------------------------
 +M85 S2700 ;Power OFF Machine if no movement for 45 minutes.
 +M140 S[bed1_temperature];Set Bed Temperature + Continue
 +M109 S120 ;Prepare Hotend for Homing Z. Set Hotend Temp 120C + WAIT
 +G28         ;Home X Y Z Axis\\
 +G1 Z100 F5000         ;Lift Z to clean the Nozzle
 +M190 S[bed1_temperature];Set Bed Temperature + Wait
 +G1 Z10 F5000 ;Z down to 10mm
 +M109 S190 ;Set Hotend Temperature + Wait
 +G92 E0         ;Reset Extruder 
 +M109 S180 B250 F1 ;Autotemp on 180...250C  
 +;STARTING GCODE END ---------------------------------------------------------------- 
 +</code>
 +Power OFF Machine if no movement for 45 minutes: Normally, this case will not occur because the axes are constantly in motion during printing. If the user stops the printer but forgets to turn it off, the A5 will turn itself off after 45 minutes to save energy.\\
  
 +\\
 +<code>
 +;ENDING GCODE START -----------------------------------------------------------------
 +G92 E0         ;Reset Extruder
 +G1 X0 Y300 Z320 E-3 F4000 ;Quick move Nozzle away while retracting 3mm Filament
 +M104 S0         ;Turn hotend off
 +M140 S0 ;Turn heatbed off
 +M109 R45 ;Cooldown and wait to reach 45C
 +M84         ;Disable steppers 
 +M81         ;Power off
 +;ENDING GCODE END -------------------------------------------------------------------
 +</code>
 +At the end of the printing process, the 3D printer waits until the hot end has cooled to 45ยฐC and then shuts itself off.\\
  
 +\\
  
 +----
  
-ย +\\ย 
-ย +//Status: 5. July 2018: Documentation complete//
-ย +
-ย +
-ย +
-ย +
-ย +
-//Status: 5. July 2018: Documentation in progress//+
a5/programmable-power-supply-control.1530786661.txt.gz ยท Last modified: 2020/12/25 02:13 (external edit)