 The changes shown here require knowledge in the field of Arduino, Marlin firmware and electrical engineering and can overwhelm normal users. Also, I would like to point out possible dangers that exist in certain interventions. All adjustments have been checked for function.  The changes shown here require knowledge in the field of Arduino, Marlin firmware and electrical engineering and can overwhelm normal users. Also, I would like to point out possible dangers that exist in certain interventions. All adjustments have been checked for function. 
  
-**Difficulty: Professional** (No more warnings. Professionals know when to unplug the mains)+**Difficulty: __Professional or Electrician__** (No more warnings. Professionals know when to unplug the mains)
  
 **What is this about?** \\  **What is this about?** \\ 
Line 63: Line 63:
 ==== Customize the Marlin firmware ==== ==== Customize the Marlin firmware ====
  
-In the Arduino IDE open the **A5 Custom Community Firmware** (see article here in WIKI).\\+In the Arduino IDE open the **A5 Custom Community Firmware** (see [[a5:firmware|article here]] in WIKI).\\
 __ __
 The following adjustments are made in the "**Configuration.h**" file:__ The following adjustments are made in the "**Configuration.h**" file:__
Line 145: Line 145:
  
 I had developed a complex special housing for the momentary switch and the solid state relay, in which the circuit should find its place. This would look like this: I had developed a complex special housing for the momentary switch and the solid state relay, in which the circuit should find its place. This would look like this:
 +
 {{:a5:aetek:ssr_pow_01.jpg}} {{:a5:aetek:ssr_pow_01.jpg}}
 +
 Electrically everything worked wonderfully. Unfortunately I noticed a problem after assembling the A5. The measurement of the available space above the momentary switch upper edge was wrong. The Y-gantry does not have enough room to move because the housing of the momentary switch was too high.\\ Electrically everything worked wonderfully. Unfortunately I noticed a problem after assembling the A5. The measurement of the available space above the momentary switch upper edge was wrong. The Y-gantry does not have enough room to move because the housing of the momentary switch was too high.\\
 \\ \\
Line 181: Line 183:
 AETEK Firmware:\\ AETEK Firmware:\\
 {{:a5:aetek:20180702-03_aetek_jgaurora_a5_custom_lcd_firmware_v3.02.zip}} \\  {{:a5:aetek:20180702-03_aetek_jgaurora_a5_custom_lcd_firmware_v3.02.zip}} \\ 
-\\+{{:a5:aetek:20180714-02_aetek_jgaurora_a5_custom_lcd_firmware_v3.02.zip}} Fix Filament Out Detection\\
  
 After the successful update of the MKS display firmware it should now look like this:\\ After the successful update of the MKS display firmware it should now look like this:\\
Line 218: Line 220:
 === Operation via software (GCODES) === === Operation via software (GCODES) ===
  
-GCODES can be sent directly to the A5 via USB, e.g. Pronterface. \\+GCODES can be sent directly to the A5 via USB, e.g. [[:pronterface|Pronterface]]. \\
 There is also the option to send stored GCODES from a storage device, such as USB stick or SD card. \\ There is also the option to send stored GCODES from a storage device, such as USB stick or SD card. \\
 Which GCODES are of interest for this project?\\ Which GCODES are of interest for this project?\\